Overview
The I-O
Xip+ Twinax Controller connects IBM and IBM compatible
Twinax display stations and printers to any
model AS400, iSeries
or System
i host
via TCP/IP over an Ethernet LAN, WAN or the
Internet. The Xip+ is ideal for those who are
moving to a new Power8 or Power7 and those migrating
any model iSeries AS/400 to an
all Ethernet environment.
The
various models of the
Xip+ support
from 1 Twinax Printer to 42 Twinax
Devices/Addresses. Click here to see the various models available.
Advantages
-
Connect
Reliable Twinax Displays and
Twinax printers to
IBM Hosts over any TCP/IP or Ethernet LAN / WAN / VPN
-
Eliminates the need for expensive IBM Twinax Work Station
Controllers
-
IP Replacement for Twinax Remote Controllers -
In locations requiring remote access, the I-O
Xip+ replaces
expensive remote controllers
-
Connects over ANY IP Connection -
No need for high-priced leased lines or expensive
DSU/CSU
modems
-
No re-cabling
- continue to utilize existing Twinax
or twisted pair cabling
-
Explicit Device Names - use the same device names you
are currently using
-
Share Printers with Up to 4 Systems or LPARs -
connect the
same Twinax Printer to multiple systems
-
Nine Different
Models Available:
LAN-RPC+ |
Support for 1 Twinax Printer
|
Xip+ 7 |
Support for 7 Twinax Devices
|
Xip+ 7D |
Desktop Version of the Xip+ 7 |
Xip+ 14 |
Support for 14 Twinax Devices
|
Xip+ 14D |
Desktop Version of the Xip+ 14 |
Xip+ 21 |
Support for 21 Twinax Devices
|
Xip+ 28 |
Support for 28 Twinax Devices
|
Xip+ 35 |
Support for 35 Twinax Devices
|
Xip+ 42 |
Support for 42 Twinax Devices
|
Click here or scroll down to see images of all Xip+ models:
-
Connect to Multiple Hosts - Supports
connection up to
four (4)
IBM Power9, Power8, Power7, or any iSeries AS/400 hosts (V3R2 or higher)
-
Supports
Multiple Protocols - TN5250e,
AnyNet and SNA
-
Easy to install
-
3-Year Advanced Exchange Warranty
(North America)
|
|
|
Click here for
more information on the Xip+ Controller
Click
here to download the Xip+ Controller Datasheet
Specifications
? General
- Attaches up to
42 Twinax
displays
and printers
- Supports up to 4 hosts
- Allows up to 4 sessions per Twinax
address - Supports TCP/IP (TN5250e, AnyNet)
and SNA protocols
• Host Systems and Requirements - AS/400-iSeries-System
i - OS400 V3R2 and newer - TCP/IP - Telnet services
• Display Stations - All 5250 Twinax display stations - Display model type is matched to
Telnet models:
5251-11,
5291-1, 5292-2,
3180-2, 3179-2, 3196-A1, 3477-FG,
3477-FC (InfoWindow II and Extended
Character Attributes not supported)
• Printers
- All 5250 SCS and IPDS Twinax
printers
- TN5250e – host configures all SCS
printers as 3812-1
- AnyNet – host recognizes the
printer’s model
type
- SNA – host recognizes the printer’s
model
type
• Data Streams
- TN5250e, auto configuring local and
remote connectivity (SCS)
- AnyNet, auto configuring local and
remote connectivity
(IPDS and SCS)
- SNA, auto configuring local
connectivity
(IPDS
and SCS)
|
• Network
- 10/100 BaseT auto-sensing
- TCP/IP (TN5250e, AnyNet)
- DHCP client
- SNA (APPC)
- Ethernet (IEEE 802.2, 802.3)
• Ports
- RJ45 for Ethernet
- Xip+ 42 - Six Twinax Host
Ports
- Xip+
35 - Five Twinax Host
Ports
- Xip+ 28
- Four Twinax Host Ports
- Xip+ 21 - Three Twinax Host
Ports
- Xip+
14 - Two Twinax Host
Ports
- Xip+ 7
- One Twinax Host Port
- DB25 parallel for diagnostic
printouts
• Approvals
- Logic Unit – FCC 15, CE
- Power Supply ? UL, CE
• Power Supply
- Input – 12 volt DC - 3
amp
• Physical - XIP+
- 19" Rack
Mountable (1.5 U)
(17"w x 6.5"d x 1.75"h)
• Physical - XIP+D Desktop
- 10"w x
9.5"d x 2.25h
|
Click here for
more information on the Xip+ Controller
Click
here to download the Xip+ Controller Datasheet
Additional Features
FEATURES |
BENEFITS |
Investment Protection |
When installing an Ethernet LAN
that is attached to an AS/400–iSeries, reliable Twinax
displays and IPDS/SCS printers can operate in the new Ethernet
environment maintaining the usefulness of the equipment |
Eliminates the Need
for Twinax Work Station Controller |
A significant saving is realized
by installing an I-O Xip+ Twinax Controller instead of an
expensive IBM Twinax Work Station Controller |
No
IBM Remote Controller
Required |
When remote access to an AS/400–iSeries
is required, an expensive IBM or IBM compatible remote controller
is replaced by an economical I–O Xip+ Controller |
No Leased Lines or
Expensive Modems |
When communicating to a remote
site, there is no need to spend valuable resources on high-priced
leased lines and special modems. |
No Re-cabling |
The I-O
Xip+ allows Twinax displays
and printers to be connected to existing Twinax or twisted pair
cabling eliminating the expense of re-cabling |
Multiple Protocols |
Supports the auto configuring
TN5250e and AnyNet for remote locations or SNA for a local attachment |
Multiple Host |
Supports up to 4 hosts |
Multiple Sessions |
Up to 4 sessions per physical
device address can be configured – Up to 56 logical sessions supported |
Click here for
more information on the Xip+ Controller
|
|
Click here
to see a larger image of each Xip+ model below to
view a larger image of it. |
|