Connect PCs On Your Ethernet Network to a Twinax
Connection on an IBM iSeries AS/400 or AS/36
PLEASE NOTE:
The TwiNet SNA Gateway is no longer
manufactured. It may be available on a refurbished basis.
Please
contact us by clicking here regarding your application and
requirements. One replacement product is the
NLynx USB Twinax Emulation Kit and is compatible with Windows
10, Windows 8 and Windows 7. Please
click
here to be taken to the
USB
Twinax page.
Overview
The TwiNet SNA Gateway
provides a simple solution for connecting Twinax IBM AS/400 and S/36
systems to your Local Area Networks (LAN). With a simple Twinax
connection to your host system, and a 10/100mb
Ethernet connection to your LAN, you can give PC users
anywhere on your network full
access to your host system as a Twinax terminal. Click
here or on the picture at right for a connectivity diagram of TwiNet.
A simple way to look at the TwiNet SNA
Gateway is as an "External Twinax Emulation Kit" that can be
shared by up to 7 PCs simultaneously.
It is fully compatible with Windows
8 and Windows 7 64-bit and 32-bit.
CompuMaster has provided
this solution that gives you a low cost SNA/LAN solutions for Printing, Terminal
Emulation, and Data Exchange in your host/LAN mixed communication
environment with TwiNet. You can also use multiple TwiNet
gateways to control multiple AS/400 or LPAR System Consoles over your TCP/IP
network.
If you need to control multiple
AS/400s or LPARs , click here for
information on our Multiple System Console
Solution (MSCS).
Featured Highlights
-
Allows any Personal Computer or TCP/IP Client
to be connected with any IBM System S/3X, AS/400 and Remote
Control Units such as 52xx, 53xx and 54xx or compatibles
-
Connects to the IBM Host
with
standard
Twinax Cable or
CAT5 cabling with Baluns
-
Supports up to seven Twinax Display or
Printer sessions (Addresses 0 through 6) on your LAN PCs with
the included TwiNet Gold Client Software for each TwiNet
Gateway installed
-
Connection to any Network
PC on your Ethernet LAN
-
Fully Compatible with
Windows 8 &7 64-bit and 32-bit, Vista, and XP
-
Built-in Web Server for
easy
installation, configuration and
monitoring
-
Manage all TwiNet's on your local LAN with
the
Network
Manager administrative software
|
Click here to receive more information
on the TwiNet SNA Twinax-to-IP Gateway
 |
|
The
picture on the left shows a standard TwiNet installation. The
IBM Host can be any S/3X, AS/400 or Remote Control Unit with a
Twinax attachment installed. TwiNet can be installed either
close to the Host or close to the Clients, using the existing
Twinax or RJ45 CAT5 cabling, very good for long distance connection (up
to 5000 feet). |
To view the Data Sheet
on TwiNet SNA to Twinax Gateway
click on the link to the right: TwiNet
Data Sheet
TwiNet allows any IBM
System i, i5, iSeries AS/400 or S/3X with Twinax,
or Remote Control Unit with Twinax attachment
installed to be connected with PCs on your LAN. TwiNet is able to
distribute up to seven (7) 5250 Display
and/or Printer sessions to these PCs.
The included TwiNet Gold Emulation Software provides the link
from the PCs to the TwiNet over the network.
TwiNet will connect to
the TwiNet Gold Client installed on any PC using Windows 7 (64- and
32-bit), Vista, and XP. More technical information is available
at the following page: TwiNet
Data Sheet
Download the TwiNet
Twinax SNA Gateway Data Sheet
Technical Specifications
Specification |
Description |
Operating System
|
PC Side: |
Windows 7, Vista, 98,
95, 2000, NT, ME |
Host Side side: |
AS/400 - Any Model with
Twinax Support |
|
Advanced Series/36: All |
|
System/36: All |
|
Connectors
|
1 RJ 45 10BaseT,
100BaseT (auto-sensing)
Twinax Y-Cable with Cable-thru capability for connection to Twinax
Host Port
|
LEDs |
Power, Link, 10/100, Check, Alert, Packet and
Collision. |
Main Power |
100-240V AC 50-60Hz |
Dimensions |
Height |
1.85 in. / |
47 mm |
Width |
8.66 in. / |
220 mm |
Depth |
5.7 in. / |
144 mm |
|
Weight |
1.65 Lb. / 0.75 Kg. |
Temperature and
Relative Humidity |
50° F to 104° F (10° C to 40° C)
8% to 85% |
Certifications |
CE ?EN 55022 ? EN 50082-1 ? FCC Class A |
Warranty |
One Year |
Click here for
More Information on the TwiNet Multiple System Console Solution
Item Number |
PRODUCT |
PURCHASE |
CMTWINETG0LD
|
TwiNet Gold Terminal Emulation Software for SNA Gateway (Twinet-100 SNA Gateway)
Includes TwiNet Gold Terminal Emulation Software and
TwiNet SNA Gateway User Guide |
$ 129.00
|
CMTWINET
|
TwiNet SNA Gateway (Twinet-100 SNA Gateway) One (1)
Twinax Host Connection 7 Twinax Device Addresses 1 required for each i5, iSeries AS/400 or LPAR host port
connection |
Call us at 800-597-2525 for availability |
Download the TwiNet
Data Sheet
CompuMaster TwiNet/TwiNetTC Connectivity Products
Form
ID 460078
For more information on TwiNet, contact us at
800-597-2525 or e-mail us at
info@twindata.com
Net-2000 TelNet Emulation Sofware Print 2000 - TCP/IP Printing Solutions for AS400 and iSeries TwiNetTC - System Console Control of Multiple i5, iSeries and AS/400s or LPARs TwiNet SNA Gateway - i5, iSeries and AS/400 and AS/36 Twinax-to-TCP/IP LAN Connectivity TwiNetTC100 - Secure TN5250e Gateway for Display and Printingi5, iSeries, AS/400PARs TwiNet SNA Gateway for System Console Control of Multiple AS/400s IPSC - IP System Console TwiNetTC - System Console Control of Multiple AS/400s or LPARs TwinXpress (TwinExpress) 5250 PCI Emulation Kit for Windows 7, Vista and X